The hpe smart array e208ip sr gen10 controller, supporting 12 gbs sas and pcie 3. Hpe storage controllers, and future devices such as scsi express drives, and sas switch devices. In the p410 manual it talks about using hp systems. Internal cabling guide for hp smart array controller cards on. Hp smart array p410 raid controller stops working after falls. I have 4 drives to setup as a raid 5 configuration but cannot figure out how to do this. The smart array controller moves the data from the cache to the drams, verifies that the data is correct, and then transfers it to the disk drives. Hewlett packard enterprise hpe smart array p420i raid.
Boot the system and clear any raid configurations previously set. In this case, be careful with the smart array p400 singledisk raid 0 setup. After the os had installed, i then updated the p410 smart array controller drivers. Hp 804398b21 smart array e208ep sr gen10 storage controller raid 8 channel sata 6gbs sas 12gbs 1. Disabling raid feature on hp smart array p400 server fault. Smart array controllers and smart host bus adapters hpe. Commercial computer software, computer software documentation, and technical data for.
Hp smart array p410 raid controller management server. Configuring arrays on hp smart array controllers reference guide. This is for the hardware guys, i have installed an ssd drive to a p410i raid controller and the io is awful does not gets more than 61mbs where this should be around 500mbs, i have changed a lot of settings on the controller, disable cache and nothing makes any difference. If i remember correctly the hp sas expander card is only officially supported with the p410 and p410i raid controllers though, not the p411 you mentioned. However the raid controller is not playing ball, on boot it recognises the drives, however at 0. Took out a 320gb stock drive out of a new notyetdeployed hp compaq 6530b laptop, put it into the tray and the p410i raid controller recognized it and offered to create a raid1 volume. May 12, 2012 this is not going to give you the performance of the jbod controller software raid card from lsi i suggested earlier, but it will certainly give you a nice improvement over what you have now. The hp smart array 5302 or 5304 controller card must be installed in pci slot 8 for internal raid. Hewlettpackard company smart array g6 controllers rev 01 subsystem. Hp smart array controllers for hp proliant servers user guide. Hp smart array p410i controller raid configuration. Hp smart array p4101gb fbwc 6gbs raid controller price.
Linux debian server work with hp smart array raid controller. To configure an array on an hp smart array controller, three utilities are available. In the create new array screen, use the arrow keys to select the first disk for the is volume. You can use the array configuration utility for several tasks such as configuring. Do this by twisting the blue paddle that locks the card in place by the. Hp branded means software products bearing a trademark or service. Solved raid issue with hp p410 and disks in wrong order.
The advantage of p400 is that it does not require a software key for raid 6 like the p410 and newer ones do. The low profile, halfheight card has 8 ports and utilizes ddr2800 memory. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. I was wondering if i would be able to raw disk map the drives through the p410 controller. Product bulletin, research or buy hp printers, desktops, laptops, servers, storage, enterprise solutions and more at the official hewlettpackard website. Where can i download the hp raid array configuration utility. Integrated smart array controllers, and hp proliant storageworks raid array. If another pci card is located in slot 8, remove that card and relocate it to another slot. Hp smart array p410i1g with fbwc storage controller. Ive just got myself an hp ml110 quad core xeon 16gb, a hp p410 raid controller, and 3 western digital red 3tb drives. Here is my personal experience with a hp smart array p410 raid controller. Hp smart array p410 256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410 256mb pcie2 int only manufacturer part number 462862b21. Hp smart array p410i1g with fbwc storage controller raid. Apr 28, 2012 once the smart array controller has initialized, pressing f9 allows you to configure the array before installing the os, which in my case is whs 2011.
Just go to the lsi website and look at their megaraid sas2 family. Software consistency among all smart array family products. Linux hp smart array raid controller sumguys ramblings. Hp proliant dl180 server smart array p410 controller accubattery duration. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement. Cant boot hp service pack for proliant to update raid. As i found out the hard way a physical raid controller is required in order to run esxi. Features 7 for registration procedures, see the configuring arrays for hp smart array controllers reference guide available on the controller documentation cd or the acu product page on the hp website. All drives in an array must be of the same type for example, all sas or all sata. Controller hp smart array p410, firmware version 1.
Software raid todays operating systems offer basic support for raid disks called software raid to create and manage logical drives that do not contain the os. Hp p410i performance problem with ssd solutions experts. Hi all we have an older proliant ml350 g6 server with a smart array p410i raid controller. The controller is running well in a parallel installation of windows server 2016 on the same hw and in the old w10 1703. Linux debian hp smart array raid controller vps hosting. If you do not press any key, you will be given a chance to run the option rom. In my case i have the hp smart array raid controller as you will see in just a bit. Although the only difference i can see is that the p411 has its two sas connectors external and it supports a maximum of 100 drives to the p410 s maximum support for 24 drives. How to use hp command line array configuration utility. In 16bay systems there is usually a p410 along with a p410i controller. Hardware installed remotely and it is difficult to reach noc every week to check drives status. My goal is to have two drives mirrored, 1 hot spare, and be able to hot swap drives, i know with the hp smart array b110i there is a license you have to get for. Theres no raid setup utility when the system boots.
I installed an hp p410 raid controller in my hp n40l proliant microserver. When the controller displays press to run the option rom configuration for arrays utility, press f8. Cabling for the hp integrity rx8620 server recabling for raid 8 chapter 1 step 3. Commercial computer software, computer software documentation, and technical data for commercial items are licensed to. But i see no way of getting notification of a drive failure other than having to manually open the hp array configuration utility software yourself. Sep 20, 2012 i have not had that experience before with dell perc controllers. Saniq patch to deliver the latest hp smart array p410 p410i raid controller firmware 3.
Option rom configuration for arrays orcaa simple utility used mainly to configure the first logical drive in a new server before the operating system is loaded. Setting up a raid array for your new hp proliant p410p410i is simple. I checked the bios and it shows the raid controller as the primary boot device. Feb 19, 20 hp proliant array configuration utility for windows 64bit. Hp proliant g6 reporting failed ssd drive alternative strategies for monitoring. Hp z600 workstation configuring raid devices hp customer. The latest hp proliant array configuration utility acu can be. Use our configuration guide to install a raid array for your hp storage controller now. I used hp s usb key utility to make a bootable usb from service pack iso, im trying to update the firmware on my p410 raid controller, this is housed in a hp n54l with ubuntu server 14. Hp smart array p410512 bbwc 2ports int pcie x8 sas controller. The low profile, half height card has 8 ports and utilizes ddr2800 memory. Second we check lspci to see what controller we have installed.
The option rom messages will go through each raid controller installed on the system. Hardware thread, replacement drives with hp smartarray p410 controllers in technical. Quickspecs hp smart array p410 controller standard features da 201worldwide version 18 january 6, 2012 page5. Hewlettpackard company smart array p410 kernel driver in use.
Some software requires a valid warranty, current hewlett packard enterprise. Hp smart array p410i controller raid configuration youtube. Jul 28, 2017 hp proliant dl180 server smart array p410 controller accubattery duration. Hp smart array p812 controller onboard expander firmware was updated to version 3. There are a lot of software on hp site for this controller. Ist ein ubertragen eines mit hpe smart array p410 controller.
Some software requires a valid warranty, current hewlett packard. The hp array configuration utility is a webbased application that helps you configure hp proliant smart2 array controllers, hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. Hp p410 raid controller and ssd oletho oct 15, 20 8. Hp p410 raid controller and sata drives not compatible. Array controllers, and hp proliant storageworks raid array controllers. It currently has a load of hp eh0300fbqdd 300gb 15k 2. The drives have not failed, but they definitely are not meant to be used with that controller. This will install the hp array drivers in preference to the supplied ones with whs 2011. Replacement drives with hp smartarray p410 controllers. This allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file. The array configuration utility cli is a commandlinebased disk configuration program for smart array controllers and raid array controllers. The plan being to create a raid 5 array across the 3 drives to give me circa 5. Jan 04, 2017 raid issue with hp p410 and disks in wrong order.
Hp smart array p410i1g with fbwc storage controller raid sata 1. P410 raid controller installation configuration on proliant dl 160 g6 i have just recently installed a p410 raid controller in a hp proliant dl 160 g6 so that i can run it with esxi. Hp smart array p410 controller hewlett packard enterprise. Hpe ssa replaces the existing hp array configuration. We purchased an hp ml350 g6 server with a p410i raid controller. The hp smart array p410 is hp s pci express pcie 2. Trying to fix some suse 11 stability issues that have marvell onboard raid controllers.